
Gas Monitoring and Pulse Oximetry
- 1st Edition - July 10, 1990
- Imprint: Butterworth-Heinemann
- Author: J.S. Gravenstein
- Language: English
- Paperback ISBN:9 7 8 - 0 - 4 0 9 - 9 0 2 6 1 - 7
- eBook ISBN:9 7 8 - 1 - 4 8 3 1 - 8 2 8 9 - 6
Gas Monitoring and Pulse Oximetry presents an extensive examination of the ventilation of the patient’s lungs. It discusses the administration of oxygen and inhalation of… Read more

Purchase options

Institutional subscription on ScienceDirect
Request a sales quoteGas Monitoring and Pulse Oximetry presents an extensive examination of the ventilation of the patient’s lungs. It discusses the administration of oxygen and inhalation of anaesthetics of patients. It addresses the methods of oxygen and carbon dioxide monitoring. Some of the topics covered in the book are the introduction to the use of capnogram; definition of oxygraphy and anesthetigraphy; mechanism of pulse oximetry; solubility of gases or vapors in water, blood, and tissue; description of anaesthesia machine with circle breathing system; and malfunction of valves and carbon dioxide absorber. The definitions and description of Mapleson breathing systems are fully covered. An in-depth account of the Jackson-Rees system is provided. The mechanism of Bain system, Lack system, and Magill system are completely presented. A chapter is devoted to description of titration of depth of anesthesia. Another section focuses on the analysis of the concentration effect, diffusion hypoxia, and cardiogenic oscillations. The book can provide useful information to clinicians, doctors, students, and researchers.
PrefaceAcknowledgments1. Introduction2. Primer for Gas Monitoring and Pulse Oximetry3. The Water Vapor Story4. Of Gas Volumes, Flows, and Time Constants5. Solubility6. Monitoring the Function of the Anesthesia Machine, the Breathing Circuit, and the Ventilator7. Titration of Depth of Anesthesia8. The Concentration Effect, Second Gas Effect, and Diffusion Hypoxia9. Cardiogenic Oscillations10. Before Induction11. General Anesthesia12. Pulse Oximetry and Monitoring of Gases in Patients under Regional or Local Anesthesia with or without Sedation13. Metabolic Changes14. Ventilation-Perfusion Inequalities15. Methods of Gas Analysis16. About Hemoglobin Saturation MeasurementsIndex
- Edition: 1
- Published: July 10, 1990
- No. of pages (eBook): 160
- Imprint: Butterworth-Heinemann
- Language: English
- Paperback ISBN: 9780409902617
- eBook ISBN: 9781483182896
Read Gas Monitoring and Pulse Oximetry on ScienceDirect